Step-By-Step
Instructions for Reconstitution and Intra-muscular Administration
Intra-muscular injection requires another person to
administer the injection. These instructions will help you
and your partner prepare and inject your medication at home.
If you have any questions, don't hesitate to call us at 800-998-4567.
 |
- Wash your hands with an antibacterial soap
and use alcohol to clean the area you will be working
on.
- Have these supplies ready:
- A vial (or vials) of LG Follimon™ and/or LG IVF-M™,
75 IU, and a vial of Sodium Chloride 0.9% (sterile
diluent) that is conveniently packaged with LG Follimon™
and LG IVF-M™, or LG IVF-C™ and a vial of Bacteriostatic
Water (sterile diluent) that is conveniently packaged
with LG IVF-C™.
- A syringe and sterile needles (check with
your doctor about which syringe and needle size
to use).
- Alcohol pads, rubbing alcohol, and gauze.
- A needle disposal container.
|
|
 |
Remember: Only the Sodium Chloride
(sterile diluent) provided must be used to reconstitute
LG Follimon™ and/or LG IVF-M™ and only the Bacteriostatic Water
(sterile diluent) provided must be used to reconstitute
LG IVF-C™.
- Remove syringe and needle from the wrapper.
While holding the protective cap, twist needle clockwise
to make sure needle is secure. Set the syringe aside.
- Remove the plastic caps from the tops of the
vials of LG Follimon™, LG IVF-M™, or LG IVF-C™ and the sterile
diluent.
- Wipe the tops of the vials with alcohol. Don't
touch the tops of the vials once you have wiped them.
- Uncap the needle by carefully twisting the
needle cap clockwise and pulling the cap upward. Avoid
twisting the needle counterclockwise, as this can cause
the needle to separate from the syringe.
- Insert the needle through the rubber stopper
of the sterile diluent vial.
- Do not tap the point of the needle against
the sides or bottom of the vial because it may dull
or bend the tip.
- Tip the sterile diluent vial and, with the
needle in the fluid, pull back on the plunger to withdraw
the fluid into the syringe up to the amount instructed
by your doctor.
- Withdraw the needle from the sterile diluent
fluid vial. Slowly inject the sterile diluent into
the vial containing the LG Follimon™, LG IVF-M™, or LG IVF-C™
powder, aiming the sterile diluent at the side of the
vial to avoid creating bubbles.
- The LG Follimon™, LG IVF-M™, or LG IVF-C™ powder will
dissolve quickly. Gently swirl until the powder is
completely dissolved. Do not shake the vial because
this will create bubbles.
- As soon as the powder has completely dissolved,
withdraw all the LG Follimon™, LG IVF-M™, or LG IVF-C™ solution
into the syringe. There are two ways of doing this:
- Leave the vial on the counter, tilt it,
pull back on the plunger to withdraw all the solution,
or
- Turn the vial upside down, pull back on
the plunger to withdraw the solution as you slowly
lower the needle.
Note: For patients who need multiple vials, the LG Follimon™ and/or LG IVF-M™ solution
may be used to dissolve up to 5 additional vials. For those who need multiple
vials, after reconstituting the first vial of LG Follimon™ and/or LG IVF-M™ with sterile
diluent, use that same solution to reconstitute the additional vials of LG Follimon™
and/or LG IVF-M™. This does not apply to LG IVF-C™.
- Hold syringe straight up. Draw back slightly
on plunger and tap syringe so that any air bubbles
rise to top. Slowly press plunger until all air is
out of syringe and a small drop of solution forms at
tip of needle.
- Tap the syringe to remove the drop of solution
at the tip of the needle.
- Carefully recap needle to keep it sterile.
- The LG Follimon™, LG IVF-M™, or LG IVF-C™ solution
is now ready for injection.
If an uncapped needle EVER comes into
contact with anything other than the LG Follimon™, LG IVF-M™,
LG IVF-C™, or sterile diluent, do not inject yourself with
it. Immediately remove the needle and replace it with
a new sterile needle. |
|
 |
- LG Follimon™, LG IVF-M™, or LG IVF-C™ should be injected
into the muscle of either the right or left upper buttock,
below the hipbone. Below, we will describe a left-side
injection.
- To locate an injection site, stand directly
behind the person who is to receive the injection.
Imagine that the left buttock is divided into quadrants.
The injection should be given in the upper left-hand
corner of the upper left-hand quadrant (see diagram).
- Swab the area with alcohol, and allow it to
air-dry.
- To relax the muscle, try standing pigeon-toed
or bending your leg slightly, placing your weight on
your other foot.
|
|
 |
|
|
 |
- Safely dispose of all used syringes in a needle
disposal container with a lid. Extra sterile diluent
or unused medication left in the vial should be thrown
away. After you finish your course of treatment, ask
your healthcare provider how to properly dispose of
the needle disposal container.
|
|
 |
- If you have a little bleeding after the injection,
don't worry. Just press the site with gauze for about
10 seconds, and cover it with an adhesive bandage.
|
|